Panasonic to Modbus TCP/RTU - Up to 64 Indoor Units
Item number IN770AIR00MO000
The Panasonic application has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 64 indoor units from a single interface.
Buy product Intesis MAPS
On this tab
Overview
- Features and benefits
- Video
- Product description
- Related accessories
- Case studies
- Related products
Features and benefits
-
Simultaneous Modbus TCP and RTU management
The gateway is a Modbus server and is able to manage both Modbus TCP and Modbus RTU simultaneously.
-
Direct access to the outdoor unit
Connection is simple, as the interface connects directly to the outdoor unit’s communication bus.
-
Automatic identification
A scan function is available for automatic identification of the units present in the VRF system.
-
Outdoor unit signals
Signals assigned to the outdoor unit are available to be used in the integration.
-
Individual indoor unit energy consumption signals
Energy consumption signals from each indoor unit are available, so they can be checked individually.
-
Multiple TCP client support
The interface supports up to 6 TCP clients (incoming sockets).
-
Commissioning-friendly approach with Intesis MAPS
Templates can be imported and reused as often as needed, significantly reducing commissioning time.
-
Configuration tool and interface automatic updates
Both the Intesis MAPS configuration tool and the interface's firmware can receive automatic updates.
Video
Related Software
Intesis MAPS
Take the complexity out of the integration process: Create your project with a predefined template, configure the needed parameters, enable the desired signals, and check the communication between the gateway and the system.
Intesis MAPS
Case studies
Air-conditioning interfaces
HVAC control for energy saving in textile retail stores
The use of Intesis gateways in the retail sector, allows ECOMT to be in full control of the HVAC system achieving comfort, energy savings and effective maintenance.
Air-conditioning interfaces
Integration of AC Systems in KNX for hotel projects
KNX AC integration for hotels: Arabian Homes uses Intesis KNX gateways for the integration of Air Conditioning Systems to KNX hotel projects.
Air-conditioning interfaces
Remote HVAC control for retail sector and office buildings
nanoGrid uses Intesis Modbus gateways for the integration of Air Conditioning systems in their retail and Energy Management projects.
Air-conditioning interfaces
Luxury high-tech holiday homes
Want to leave your hectic urban life behind to soak up the full beauty of nature and enjoy a completely serene environment? Want to do this with all the comforts of modern living? Now you can! Thanks to Cuber and Intesis.
Air-conditioning interfaces
Ray Castle Hotel & Resort Project
Intesis provided KNX centralized gateways to connect LG units to JUNG’s control system.
Air-conditioning interfaces
KNX Award Winning Baku White House
Intesis gateways integrate air conditioning into fully-automated residential property, leading to an award-winning entry in the KNX Awards.
Air-conditioning interfaces
Energy saving in retail premises with Intesis gateways
The UK’s largest pets supplies retailer is enjoying significant energy savings across its entire retail network, while ensuring that ideal animal welfare conditions are maintained at all times.
Air-conditioning interfaces
HVAC integration in 280 hotel rooms
Room level integration of 280 AC units with a local controller.
Air-conditioning interfaces
Automated Home
The client wanted a home with automated services, security and luxury features that was easy to operate, while celebrating the history of the building.
Air-conditioning interfaces
AC Control in Control4 showrooms
A home automation showroom in the heart of Chelsea is making extensive use of Intesis Wi-Fi communication interfaces to reduce hard wiring and enable easy and frequent reconfiguration.
Related products
- Panasonic ECOi, PACi, ECOg / PAC, VRF systems to Home Automation Application Panasonic to Home Automation - Up to 64 Indoor Units Order code: IN770AIR00MO000 The Panasonic application has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a Home Automation system.The solution allows the integration of up to 64 indoor units from a single interface. Panasonic ECOi, PACi, ECOg / PAC, VRF systems to Modbus TCP/RTU Replaced by: IN770AIR00SO000 Order code: INMBSPAN016O000 This Panasonic application was designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allowed the integration of up to 16 indoor units from a single interface. Please refer to the new product reference for further details. Mitsubishi Heavy Industries VRF systems to Home Automation Application Mitsubishi Heavy Industries to Home Automation - Up to 4 Indoor Units Order code: IN776MHIXXSO000 The Mitsubishi Heavy Industries application has been specially designed to allow bidirectional control and monitoring of Mitsubishi Heavy Industries VRF systems from a Home Automation system.The solution allows the integration of up to 4 indoor units from a single interface. Samsung NASA VRF systems to Home Automation Application Samsung to Home Automation - Up to 64 Indoor Units Order code: IN770AIR00MO000 The Samsung application has been specially designed to allow bidirectional control and monitoring of Samsung NASA VRF systems from a Home Automation system.The solution allows the integration of up to 64 indoor units from a single interface. Hitachi VRF systems to Modbus TCP/RTU Replaced by: IN770AIR00SO000 Order code: INMBsh*t016O000 This Hitachi application was designed to allow bidirectional control and monitoring of Hitachi VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allowed the integration of up to 16 indoor units from a single interface. Please refer to the new product reference for further details. Mitsubishi Heavy Industries VRF systems to Home Automation Application Mitsubishi Heavy Industries to Home Automation - Up to 16 Indoor Units Order code: IN776MHI00SO000 The Mitsubishi Heavy Industries application has been specially designed to allow bidirectional control and monitoring of Mitsubishi Heavy Industries VRF systems from a Home Automation system.The solution allows the integration of up to 16 indoor units from a single interface. Panasonic ECOi, PACi, ECOg / PAC, VRF systems to Modbus TCP/RTU Application Panasonic to Modbus TCP/RTU - Up to 16 Indoor Units Order code: IN770AIR00SO000 The Panasonic application has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 16 indoor units from a single interface. Mitsubishi Heavy Industries VRF systems to Modbus TCP/RTU Application Mitsubishi Heavy Industries to Modbus TCP/RTU - Up to 16 Indoor Units Order code: IN776MHI00SO000 The Mitsubishi Heavy Industries application has been specially designed to allow bidirectional control and monitoring of Mitsubishi Heavy Industries VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 128 indoor units from a single interface. Hitachi VRF systems to Modbus TCP/RTU Application Hitachi to Modbus TCP/RTU - Up to 64 Indoor Units Order code: IN770AIR00MO000 The Hitachi application has been specially designed to allow bidirectional control and monitoring of Hitachi VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 64 indoor units from a single interface. Samsung NASA VRF systems to KNX Application Samsung to KNX - Up to 4 Indoor Units Order code: IN770AIRXXSO000 The Samsung application has been specially designed to allow bidirectional control and monitoring of Samsung NASA VRF systems from a KNX installation.The solution allows the integration of up to 4 indoor units from a single interface. Mitsubishi Heavy Industries VRF systems to KNX Application Mitsubishi Heavy Industries to KNX - Up to 16 Indoor Units Order code: IN776MHI00SO000 The Mitsubishi Heavy Industries application has been specially designed to allow bidirectional control and monitoring of Mitsubishi Heavy Industries VRF systems from a KNX installation.The solution allows the integration of up to 16 indoor units from a single interface. Samsung NASA VRF systems to Modbus TCP/RTU Replaced by: IN770AIRXXSO000 Order code: INMBSSAM004O000 This Samsung application was designed to allow bidirectional control and monitoring of Samsung NASA VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client. The solution allowed the integration of up to 4 indoor units from a single interface. Please refer to the new product reference for further details. Fujitsu VRF systems to KNX Application Fujitsu to KNX - Up to 64 Indoor Units Order code: IN775FGL00MO000 The Fujitsu application has been specially designed to allow bidirectional control and monitoring of Fujitsu VRF systems from a KNX installation.The solution allows the integration of up to 64 indoor units from a single interface. Mitsubishi Electric City Multi systems to Modbus TCP/RTU Application Mitsubishi Electric to Modbus TCP/RTU - Up to 50 groups Order code: IN770AIR00SO000 The Mitsubishi Electric application has been specially designed to allow bidirectional control and monitoring of Mitsubishi Electric City Multi systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 50 groups from a single interface. Hitachi VRF systems to KNX Replaced by: IN770AIR00SO000 Order code: INKNXHIT016O000 This Hitachi application was designed to allow bidirectional control and monitoring of Hitachi VRF systems from a KNX installation.The solution allowed the integration of up to 16 indoor units from a single interface. Please refer to the new product reference for further details. Panasonic ECOi, PACi, ECOg / PAC, VRF systems to BACnet IP/MSTP Replaced by: IN770AIR00SO000 Order code: INBACPAN016O000 This Panasonic application was designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a BMS, SCADA, PLC, or any other device working as a BACnet/IP server or a BACnet MS/TP client.The solution allowed the integration of up to 16 indoor units from a single interface. Please refer to the new product reference for further details. Mitsubishi Heavy Industries VRF systems to Home Automation Application Mitsubishi Heavy Industries to Home Automation - Up to 128 Indoor Units Order code: IN776MHI00LO000 The Mitsubishi Heavy Industries application has been specially designed to allow bidirectional control and monitoring of Mitsubishi Heavy Industries VRF systems from a Home Automation system.The solution allows the integration of up to 128 indoor units from a single interface. Fujitsu VRF systems to Home Automation Application Fujitsu to Home Automation - Up to 64 Indoor Units Order code: IN775FGL00MO000 The Fujitsu application has been specially designed to allow bidirectional control and monitoring of Fujitsu VRF systems from a Home Automation system.The solution allows the integration of up to 64 indoor units from a single interface. Panasonic ECOi, PACi, ECOg / PAC, VRF systems to KNX Application Panasonic to KNX - Up to 64 Indoor Units Order code: IN770AIR00MO000 The Panasonic application has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a KNX installation.The solution allows the integration of up to 64 indoor units from a single interface. Samsung NASA VRF systems to Modbus TCP/RTU Application Samsung to Modbus TCP/RTU - Up to 4 Indoor Units Order code: IN770AIRXXSO000 The Samsung application has been specially designed to allow bidirectional control and monitoring of Samsung NASA VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 4 indoor units from a single interface. Hitachi VRF systems to BACnet IP/MSTP Replaced by: IN770AIR00MO000 Order code: INBACHIT064O000 This Hitachi application was designed to allow bidirectional control and monitoring of Hitachi VRF systems from a BMS, SCADA, PLC, or any other device working as a BACnet/IP server or BACnet MS/TP client. The solution allowed the integration of up to 64 indoor units from a single interface. Please refer to the new product reference for further details. Samsung NASA VRF systems to KNX Application Samsung to KNX - Up to 64 Indoor Units Order code: IN770AIR00MO000 The Samsung application has been specially designed to allow bidirectional control and monitoring of Samsung NASA VRF systems from a KNX installation.The solution allows the integration of up to 64 indoor units from a single interface. Panasonic ECOi, PACi, ECOg / PAC, VRF systems to Modbus TCP/RTU Application Panasonic to Modbus TCP/RTU - Up to 64 Indoor Units Order code: IN770AIR00MO000 The Panasonic application has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 64 indoor units from a single interface. Fujitsu VRF systems to Modbus TCP/RTU Application Fujitsu to Modbus TCP/RTU - Up to 16 Indoor Units Order code: IN775FGL00SO000 The Fujitsu application has been specially designed to allow bidirectional control and monitoring of Fujitsu VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 16 indoor units from a single interface. Fujitsu VRF systems to Modbus TCP/RTU Application Fujitsu to Modbus TCP/RTU - Up to 4 Indoor Units Order code: IN775FGLXXSO000 The Fujitsu application has been specially designed to allow bidirectional control and monitoring of Fujitsu VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 4 indoor units from a single interface. Panasonic ECOi, PACi, ECOg / PAC, VRF systems to KNX Application Panasonic to KNX - Up to 4 Indoor Units Order code: IN770AIRXXSO000 The Panasonic application has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a KNX installation.The solution allows the integration of up to 4 indoor units from a single interface. Samsung NASA VRF systems to Home Automation Application Samsung to Home Automation - Up to 4 Indoor Units Order code: IN770AIRXXSO000 The Samsung application has been specially designed to allow bidirectional control and monitoring of Samsung NASA VRF systems from a Home Automation system.The solution allows the integration of up to 4 indoor units from a single interface. Panasonic ECOi, PACi, ECOg / PAC, VRF systems to Home Automation Application Panasonic to Home Automation - Up to 16 Indoor Units Order code: IN770AIR00SO000 The Panasonic application has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, PACi, ECOg / PAC, VRF systems from a Home Automation system.The solution allows the integration of up to 16 indoor units from a single interface. Samsung NASA VRF systems to Home Automation Application Samsung to Home Automation - Up to 16 Indoor Units Order code: IN770AIR00SO000 The Samsung application has been specially designed to allow bidirectional control and monitoring of Samsung NASA VRF systems from a Home Automation system.The solution allows the integration of up to 16 indoor units from a single interface. Samsung NASA VRF systems to Modbus TCP/RTU Replaced by: IN770AIR00SO000 Order code: INMBSSAM008O000 This Samsung application was designed to allow bidirectional control and monitoring of Samsung NASA VRF systems from a BMS, SCADA, PLC, or any other device working as a Modbus client. The solution allowed the integration of up to 8 indoor units from a single interface. Please refer to the new product reference for further details. Toshiba VRF systems to KNX Interface Toshiba to KNX - 64 indoor units Order code: INKNXTOS064O000 The Toshiba interface has been specially designed to allow bidirectional control and monitoring of Toshiba VRF systems from a KNX installation. The gateway is directly connected to the outdoor unit's communication bus and enables control of all the indoor units connected to the system. Mitsubishi Electric City Multi systems to KNX Application Mitsubishi Electric to KNX - Up to 100 groups Order code: IN770AIR00MO000 The Mitsubishi Electric application has been specially designed to allow bidirectional control and monitoring of Mitsubishi Electric City Multi systems from a KNX installation.The solution allows the integration of up to 100 groups from a single interface. Mitsubishi Electric City Multi systems to Modbus TCP/RTU Application Mitsubishi Electric to Modbus TCP/RTU - Up to 100 groups Order code: IN770AIR00MO000 The Mitsubishi Electric application has been specially designed to allow bidirectional control and monitoring of Mitsubishi Electric City Multi systems from a BMS, SCADA, PLC, or any other device working as a Modbus client.The solution allows the integration of up to 100 groups from a single interface.
On this tab
Specifications
- Technical specifications
- Use cases
- Common videos
Technical specifications
Content of Delivery
Intesis Gateway, Installation Manual, USB Configuration cable.
Not Included (in delivery)
Power supply not included.
Net Width (mm)
106 mm
Net Height (mm)
58 mm
Net Depth (mm)
90 mm
Net Weight (g)
240 g
Mounting
DIN rail mount (bracket included), Wall mount
Operating Temperature °C Min
0 °C
Operating Temperature °C Max
60 °C
Housing Materials
Plastic
Packaging Material
Cardboard
Warranty (years)
3 years
Capacity
Up to 64 indoor units and up to 32 outdoor units.
Installation Conditions
This gateway is designed to be mounted inside an enclosure. If the unit is mounted outside an enclosure, precautions should always be taken to prevent electrostatic discharge to the unit. When working inside an enclosure (e.g., making adjustments, setting switches, etc.), typical anti-static precautions should always be followed before touching the unit.
CE
Yes
UL
Yes
WEEE Category
IT and telecommunications equipment
CB
Yes
UKCA
Yes
UKPSTI
Yes
ETIM Classification
EC001604
Contains Battery
No
LED Indicators
Gateway and communication status.
Push Buttons
Factory reset.I-Am message (for BACnet only).Normal mode/programming mode switch (for KNX only).
Brand
Intesis
Country of Origin
Spain
Dual Usage
No
Export Control Classification Number (ECCN)
EAR99
Item Number
IN770AIR00MO000
Product Lifecycle State
Active
Use Case
Integration example.
Multiple Protocol Combinations
Use Intesis MAPS to change the protocol: BACnet, Modbus, KNX, or Home Automation
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Use Case
Integration example.
Multiple Protocol Combinations
Use Intesis MAPS to change the protocol: BACnet, Modbus, KNX, or Home Automation
Multiple Protocol Combinations
Use Intesis MAPS to change the protocol: BACnet, Modbus, KNX, or Home Automation
Multiple Protocol Combinations
Use Intesis MAPS to change the protocol: BACnet, Modbus, KNX, or Home Automation
Multiple Protocol Combinations
Use Intesis MAPS to change the protocol: BACnet, Modbus, KNX, or Home Automation
Multiple Protocol Combinations
Use Intesis MAPS to change the protocol: BACnet, Modbus, KNX, or Home Automation
On this tab
Buy product
- How to buy
- Need help?
- Ordering information
How to buy
Find certified distributor
Distributors provide first-line technical support and local language assistance (not for Embedded products).
Order from HMS
If you´re already an HMS customer, or would like to become one.
Find e-commerce partner
Find e-commerce partner
Need help?
Can't find a distributor or partner or need help to figure out which partner suits you?
No problem, you can always contact your nearest HMS office and let our sales and customer service staff take care of your enquiry.
Contact us How to buy
Ordering information
Item number: IN770AIR00MO000
Warranty: 3 years
Contents of delivery
Included Components: Intesis Gateway, Installation Manual, USB Configuration cable.
Not included: Power supply not included.
On this tab
Support and downloads
- First Time Use
- FAQ: Knowledge base articles
- Downloads
- Services and trainings
Downloads, documentation and resources
Download
To download this file you need to submit your email address. You will then get an email with the download link
Invalid email address
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
Discover all you can do with this product. This document includes all the applications and their wiring diagrams. | Wiring Diagrams - Product applications | 1.5 MB | 4194d105-22ce-6706-92f4-ff00001bbfd4 Download | ||
CAD Drawings 2D and 3D | zip | 4.2 MB | 90e6e605-22ce-6706-92f4-ff00001bbfd4 Download |
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
UKPSTI Certification | 279.4 KB | 0c350be4-cb4a-45ed-9be5-5da029170f1b Download | |||
CE Declaration of Conformity | 193.6 KB | 8529d505-22ce-6706-92f4-ff00001bbfd4 Download | |||
UK Declaration of Conformity | UKCA Declaration | 126.2 KB | 402ad505-22ce-6706-92f4-ff00001bbfd4 Download |
Installation guides
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
Installation Guide | 2.0.4 | 1.6 MB | 2229d505-22ce-6706-92f4-ff00001bbfd4 Download |
Reference guides
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
Please refer to the Intesis compatibility tool for updated information. Our database is in continuous growth. | Panasonic Compatibility list for the APAC region | 1.0.1 | 85.5 KB | 2207eb05-22ce-6706-92f4-ff00001bbfd4 Download |
Manuals
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
Gateway configuration guide for Panasonic | Intesis MAPS User Manual | 1.0.3 | 3.9 MB | 8d2ad505-22ce-6706-92f4-ff00001bbfd4 Download | |
User Manual | 1.1.2 | 2.7 MB | a127d505-22ce-6706-92f4-ff00001bbfd4 Download |
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
This application note includes recommendations to avoid polarity issues inRS485 networks. | Recommendations to avoid polarity issues | 138.3 KB | aa354a60-621b-441d-a24d-7ee1ceeff5f8 Download | ||
This document describes how to estimate each indoor unit's energy consumption using Intesis 700 Series Air gateways, and its Power Estimation Algorithm. | Application note: The Power Estimation Algorithm. | 7.1 MB | 0c128630-513a-4035-93e7-86108c616c9a Download |
Additional Resources
Intesis HVAC Compatibility Tool
The latest Intesis HVAC Compatibility Tool helps find the right gateway to integrate any HVAC system, by simply entering the brand and model. Users can also submit compatibility requests, so the information is updated regularly.
Find certified distributor
Distributors provide first-line technical support and local language assistance (not for Embedded products).
Order from HMS
If you´re already an HMS customer, or would like to become one.
Find e-commerce partner
Find e-commerce partner
Services and training
Training with HMS Academy
Training from HMS Academy reduces the total cost and time of your project and gives improved quality and efficiency of the solution.
HMS offers trainings related to products, technologies and more. This could be in the form of an onsite training, online training or by running one of our E-learning sessions.
HMS Academy
Technical services
Technical Services from HMS helps customers with any type of assistance needed in addition to the products bought from HMS. The Technical Services page offers a list of all services we provide.
The services are provided by HMS’ global team of skilled and experienced engineers who work together with you, providing various services.
Typical activities are project planning, setting up evaluation demos, creating and validating product configurations, providing guidance during field trials, and more.
Technical services
Still need help?
Contact support
Technical Services from HMS helps customers with any type of assistance needed in addition to the products bought from HMS. The Technical Services page offers a list of all services we provide.
The services are provided by HMS’ global team of skilled and experienced engineers who work together with you, providing various services.
Typical activities are project planning, setting up evaluation demos, creating and validating product configurations, providing guidance during field trials, and more.
Send support ticket
Discuss in the forum
If you would like to discuss with other people with the same interest please reach out through our forum
Forum
Sustainability
HMS strives to minimize the climate impact in our own operations and in the value chain.
Sustainability
Production
In modern production facilities, HMS manufactures industrial communication products with extreme quality demands.
Production